Triple vane hydraulic pumps incorporate three sets of vanes, further increasing their capacity for flow and pressure. This configuration enhances the efficiency and reduces the pulsation effects even more than double vane pumps. The triple vane design is ideal for high-demand applications where consistent performance and high output are critical, such as in industrial and mobile machinery.
Max pressure: 270 bar
Max speed: 2400 rpm
Max flow: (P1=003-031)(P2=002-014)(P3=002-014) gpm
Max displacement: 23-180 cm3/rev
Mounting standards: SAE J744 SAE-B
Max pressure: 270 bar
Max speed: 2400 rpm
Max flow: (P1=003-031)(P2=003-031)(P3=002-014) gpm
Max displacement: 28-240 cm3/rev
Mounting standards: SAE J744 SAE-B
Max pressure: 290 bar
Max speed: 2400 rpm
Max flow: (P1=014-050)(P2=002-015)(P3=002-015) gpm
Max displacement: 56-258 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 290 bar
Max speed: 2400 rpm
Max flow: (P1=014-050)(P2=002-015)(P3=002-015) gpm
Max displacement: 56-258 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 290 bar
Max speed: 2400 rpm
Max flow: (P1=014-050)(P2=014-050)(P3=002-015) gpm
Max displacement: 94-366 cm3/rev
Mounting standards: ISO 3019-2 125 B4 HW
Max pressure: 290 bar
Max speed: 2400 rpm
Max flow: (P1=014-050)(P2=014-050)(P3=002-015) gpm
Max displacement: 94-366 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 290 bar
Max speed: 2350 rpm
Max flow: (P1=014-050)(P2=003-031)(P3=002-015) gpm
Max displacement: 61-308 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 270 bar
Max speed: 2400 rpm
Max flow: (P1=014-050)(P2=003-031)(P3=003-031) gpm
Max displacement: 66-358 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 290 bar
Max speed: 2450 rpm
Max flow: (P1=014-061)(P2=002-015)(P3=002-015) gpm
Max displacement: 60-290 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 290 bar
Max speed: 2300 rpm
Max flow: (P1=014-061)(P2=003-031)(P3=002-015) gpm
Max displacement: 64-341 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 270 bar
Max speed: 2300 rpm
Max flow: (P1=014-061)(P2=003-031)(P3=003-031) gpm
Max displacement: 66-358 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 270 bar
Max speed: 2350 rpm
Max flow: (P1=014-061)(P2=014-050)(P3=003-031) gpm
Max displacement: 99-416 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 260 bar
Max speed: 2400 rpm
Max flow: (P1=014-061)(P2=003-031)(P3=002-014) gpm
Max displacement: 65-330 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 270 bar
Max speed: 2400 rpm
Max flow: (P1=014-061)(P2=003-031)(P3=003-031) gpm
Max displacement: 70-390 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 270 bar
Max speed: 2400 rpm
Max flow: (P1=014-061)(P2=003-031)(P3=003-031) gpm
Max displacement: 70-390 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 270 bar
Max speed: 2400 rpm
Max flow: (P1=014-061)(P2=014-061)(P3=003-031) gpm
Max displacement: 107-480 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 270 bar
Max speed: 2400 rpm
Max flow: (P1=014-061)(P2=014-061)(P3=003-031) gpm
Max displacement: 107-480 cm3/rev
Mounting standards: SAE J744 SAE-C
Max pressure: 270 bar
Max speed: 2100 rpm
Max flow: (P1=042-085)(P2=014-061)(P3=003-031) gpm
Max displacement: 191-560 cm3/rev
Mounting standards: ISO 3019-2 250 B4 HW
Max pressure: 270 bar
Max speed: 2100 rpm
Max flow: (P1=042-085)(P2=014-061)(P3=003-031) gpm
Max displacement: 191-560 cm3/rev
Mounting standards: SAE J744 SAE-E
Max pressure: 285 bar
Max speed: 2150 rpm
Max flow: (P1=042-085)(P2=014-050)(P3=002-015) gpm
Max displacement: 182-478 cm3/rev
Mounting standards: ISO 3019-2 250 B4 HW
Max pressure: 285 bar
Max speed: 2150 rpm
Max flow: (P1=042-085)(P2=014-050)(P3=002-015) gpm
Max displacement: 182-478 cm3/rev
Mounting standards: SAE J744 SAE-E
Max pressure: 290 bar
Max speed: 2400 rpm
Max flow: (P1=042-085)(P2=014-061)(P3=002-015) gpm
Max displacement: 186-510 cm3/rev
Mounting standards: ISO 3019-2 250 B4 HW
Max pressure: 270 bar
Max speed: 2150 rpm
Max flow: (P1=042-085)(P2=014-050)(P3=003-031) gpm
Max displacement: 187-528 cm3/rev
Mounting standards: ISO 3019-2 250 B4 HW